Contact Us

Life Sciences
Life Sciences

Temperature Sensors: TFP Temperature sensor with built-in system PHARMadapt EPA-18

Aseptic temperature measurement for tubes from DN10 and vessels, installation with built-in system PHARMadapt EPA-18

Types: TFP-841 / TFP-861 / TFP-881

  • Aseptic temperature measurement, inline, precise and fast
  • Process connection with sealing ring for simple removal in case of cleaning or maintenance
  • 3A conform
  • Extremely robust and long lasting, completely made of stainless steel

Know more about different types of hygienic Temperature Sensors by Anderson-Negele.

Product Information:

Technical Specification

Process ConnectionPHARMadapt EPA-18
Insertion length20, 50 mm
Wetted materialStainless steel 1.4435 (316L), Ra≤0.8 μm with 3.1 certificate
Measuring range-50…+250°C
AccuracyA | 1/3B | 1/10B
Available versionsHead ø18 mm | ø50 mm
Operating pressuremax. 10 bar
CommunicationPt100, 4..20 mA
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information