Types: TFP-42.2 / TFP-52.2 / TFP-62 / TFP-182.2
Flow optimized temperature measurement for tubes from DN15 on and vessels, with hygienic thread M12 (CLEANadapt) and 2xPt100
Note: Discover now the new generation for MINI sensors TSMF: Just click here!
Process Connection | CLEANadapt M12 |
Insertion length | 20..500 mm |
Wetted material | Stainless steel 1.4404 (316L), Ra≤0.8 μm |
Measuring range | -50…+250°C, Option up to +450°C |
Accuracy | A | 1/3B | 1/10B |
Available versions | Head ø18 mm | ø55 mm | High-temperature |
Operating pressure | max. 50 bar |
Communication | Pt100, 4..20 mA |
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information |