Flow monitoring in pipes from DN25 on of media with particles > 50 µm, like drinking water, milk….
| Process Connection | CLEANadapt G1/2" |
| Insertion length | Stainless steel 1.4404 (316L), Ra≤0.8 μm |
| Measuring range | 0,1…2,5 m/s |
| Accuracy | ±10% of the end value |
| Temperature range process | 0…100 °C |
| Temperature range CIP/SIP | 100 °C continuous |
| Operating pressure | max. 10 bar |
| Communication | 4…20 mA / PNP |
| The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information | |