Magnetic inductive flow and volume measurement of media with a minimum conductivity >5 µS/cm
Process Connection | Aseptic flange | Aseptic thread | FG hygienic flange | DIN flange | welded flange | Tri-Clamp | Varivent | SMS | Dairy tube |
Insertion length | Stainless steel 1.4404 (316L) | 1.4435 Ra≤0.4 μm (electropolished) | Tube PFA |
Measuring range | "0,1…10 m/s 30…300.000 l/h" |
Accuracy | ±0,2% ± 1mm/s |
Available versions | Compact | Remote |
Temperature range process | Compact: 0...100 °C / 32...212 °F | Remote: 0...165 °C / 32...329 °F |
Temperature range CIP/SIP | Compact: 130 °C / 266 °F max. 30 Min. |
Operating pressure | max. 17 bar absolute |
Communication | 4…20 mA |
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information |