Food, Beverage and Dairy
Food, Beverage and Dairy

NCS …L60 Point level sensor for double-walled vessels, with thread G1/2″ (CLEANadapt)

Point Level Sensors

Gap optimized, capacitive limit detection in double walled metallic vessels with hygienic thread G ½” (CLEANadapt)

  • Version with extended installation length for double walled / insulated vessels
  • Reliable detection, unaffected by the conductivity of the medium
  • Insensitive to foam
  • Extended measuring range from Dk ≥ 2 for difficult media
  • Very short response time <1 s
  • For water based media with Dk>= 20
  • Independent of the conductivity of the medium
  • Easy cleaning
  • Heated electronics to avoid condensation
Product Information:

Technical Specification

Process Connection CLEANadapt G1/2" | Adapter for Tri-Clamp, Varivent, DRD, Dairy flange
Insertion length 50, 100, 150, 200 mm
Wetted material Stainless steel 1.4404 (316L) Ra≤0.8 μm | PEEK
Measuring range Dk ≥ 20
Available versions Insertion length selectable | Various temperature options (e.g. heated electronics)
Temperature range process up to 140 °C
Temperature range CIP/SIP 143 °C / max. 120 min.
Operating pressure max. 10 bar
Communication PNP | NPN
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information