Point Level Sensors: NVS-146.w Point level sensor for hazardous media (WHG)

Conductive limit detection in vessels with hygienic thread (CLEANadapt)

  • Point level measurement in tanks and pipes of non-combustible media that is hazardous to water with a minimum conductivity of 10 µS/cm
  • Meets the legal requirements of the German Federal Water Act (WHG)
  • For use in LAU installations (plants for storage, filling and conversion of substances hazardous to water such as chemicals and their mixtures)
  • Technical Approval Z-65.13-238 by Deutsches Institut für Bautechnik (DIBt)
Product Information:

Technical Specification

Process ConnectionCLEANadapt G1/2" oder G1"| Adapter for Tri-Clamp, Varivent, APV, Dairy flange
Insertion length200, 500, 850, 1000, 1500, 2000 mm (possible to shorten / bend rod)
Wetted materialStainless steel 1.4404 (316L) Ra≤0.8 μm | PEEK | Coating PFA
Measuring rangeMinimum conductivity 1 μS/cm
Available versionsSingle rod | Dual rod
Temperature range process0…140 °C
Temperature range CIP/SIP143 °C / max. 120 min.
Operating pressuremax. 10 bar
CommunicationPNP
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information