Food, Beverage and Dairy
Food, Beverage and Dairy

NCS-01 / NCS-02 Point level sensor with thread M12 (CLEANadapt)

Point Level Sensors

Gap optimized, capacitive limit detection in metallic vessels and pipes with hygienic thread M12 (CLEANadapt)

  • Reliable detection, unaffected by the conductivity of the medium
  • Insensitive to foam
  • Independent of the conductivity of the medium
  • Measuring range from Dk ≥ 5 for difficult media such as oils, fats…
  • Very short response time
  • Compact size and easy cleaning
Product Information:

Technical Specification

Process Connection CLEANadapt M12 | Adapter for Tri-Clamp, Varivent, APV, Dairy flange
Insertion length 9 mm
Wetted material Stainless steel 1.4404 (316L) Ra≤0.8 μm | PEEK
Measuring range Dk ≥ 5/ Dk ≥ 20
Available versions Insertion length selectable | Various temperature options (e.g. heated electronics)
Temperature range process up to 140 °C
Temperature range CIP/SIP 141 °C / max. 120 min.
Operating pressure max. 10 bar
Communication PNP | NPN
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information

Application

Download

Product Information:

Process Connection

Configuration and 3D Data