Dairy, Food & Beverage
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
DART | Temperature monitoring in the pasteurizer | Digital reference thermometer for pasteurization and autoclaves („Retort“); Meets PMO requirements (Pasteurized Milk Organization) | more | ||
![]() |
DTG | Digital Temperature measurement in tubes and vessels | Temperature gauge with digital display, no external power supply; Optionally with switch output and external power supply | more | ||
![]() |
NFP-41 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, with integrated level detection | more | ||
![]() |
TFP-06 | Temperature measurement in tubes and vessels | without thread, fixed cable without wiring head | ![]() |
more | |
![]() |
TFP-100-BAT | Temperature measurement in tubes and vessels | for pipes down to DN25, with integrated level detection | more | ||
![]() |
TFP-160, TFP-180 | Temperature measurement in tubes and vessels | thread G1/2" standard, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-161, TFP-181 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-162, TFP-182 | Temperature measurement in tubes with CLEANadapt M12 | for pipes down to DN15, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-164, TFP-184 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, wiring head 18 mm, front flush mounting | ![]() |
more | |
![]() |
TFP-169, TFP-189 | Temperature measurement in tubes and vessels | without thread, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-17, TFP-18 | Temperature measurement in vessels and rooms | connecting box out of polyamide plastic | more | ||
![]() |
TFP-179, TFP-199 | Temperature measurement in tubes without process opening with FLEXadapt ESF | for pipes down to DN25, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-40, TFP-50 | Temperature measurement in tubes and vessels | thread G1/2" standard, wiring head 55 mm | ![]() |
more | |
![]() |
TFP-41, TFP-51 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, wiring head 55 mm, option: high temperature version TFP-51 | ![]() |
more | |
![]() |
TFP-414, TFP-614 | Temperature measurement in tubes and vessels for weld in sleeves and adaptors type "Hengesbach QUICKTEMP" | Insertion length 117 mm wit G1/4" thread | more | ||
![]() |
TFP-42, TFP-52 | Temperature measurement in tubes with CLEANadapt M12 | for pipes down to DN15, wiring head 55 mm, option: high temperature version TFP-52 | ![]() |
more | |
![]() |
TFP-44, TFP-54 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, wiring head 55 mm, front flush mounting | ![]() |
more | |
![]() |
TFP-49 | Temperature measurement in tubes and vessels | without thread, wiring head 55 mm | ![]() |
more | |
![]() |
TFP-59 | Temperature measurement in tubes without process opening with FLEXadapt ESF | for pipes down to DN25, wiring head 55 mm, spring loaded sensor element | ![]() |
more | |
![]() |
TFP-60 | Temperature measurement in tubes and vessels | thread G1/2" standard, prepared for 2xtransmitter | ![]() |
more | |
![]() |
TFP-61 | Temperature measurement in tubes with CLEANadapt G1/2" | for pipes down to DN25, prepared for 2xtransmitter | ![]() |
more | |
![]() |
TFP-69 | Temperature measurement in tubes and vessels | without thread, prepared for 2xtransmitter | ![]() |
more | |
![]() |
TFP-RA, TFP-RK | Temperature measurement in tubes | pipe contact sensor for pipes up to DN250 | more | ||
![]() |
TFP-xx-MV | Temperature measurement in tubes and vessels | type tested for usage in milk heating fcilities | more |
Pharma
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
TFP-162P, TFP-182P | Temperature measurement in tubes with CLEANadapt M12 | for pipes down to DN15, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-168P, TFP-188P | Aseptic temperature measurement in tubes without process opening | for pipes down to DN10, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-42P, TFP-52P | Temperature measurement in tubes with CLEANadapt M12 | for pipes down to DN15, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-58P | Aseptic temperature measurement in tubes without process opening | for pipes down to DN10, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-641, TFP-642 | Aseptic temperature measurement in tubes with O-ring and clamp fixture | connection EPA-8, for pipes down to DN10, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-661, TFP-681 | Aseptic temperature measurement in tubes with O-ring and clamp fixture | connection EPA-8, for pipes down to DN10, wiring head 18 mm | ![]() |
more | |
![]() |
TFP-68P | Aseptic temperature measurement in tubes without process opening | for pipes down to DN10, prepared for 2xtransmitter | more | ||
![]() |
TFP-841, TFP-842 | Aseptic temperature measurement in tubes with O-ring and clamp fixture | connection EPA-18, for pipes down to DN25, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-861, TFP-881 | Aseptic temperature measurement in tubes with O-ring and clamp fixture | connection EPA-18, for pipes down to DN25, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-90 | Temperature measurement in tanks & vessels with fermenter connection | connection G 1 1/4" coupling nut, wiring head 50 mm | ![]() |
more | |
![]() |
TFP-96, TFP-98 | Temperature measurement in tanks & vessels with fermenter connection | connection G 1 1/4" coupling nut, wiring head 18 mm | ![]() |
more |
Temperature transmitter and controller
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
MPU-10 | Transmitter for wiring head 50 mm and 55 mm | free programmable Profibus PA | more | ||
![]() |
MPU-4B | Transmitter for wiring head 50 mm and 55 mm | free programmable analog 4…20 mA | more | ||
![]() |
MPU-H | Transmitter for wiring head 50 mm and 55 mm | free programmable analog 4…20 mA, HART-communication | more | ||
![]() |
MPU-LCD | transmitter for wiring head 50 mm and 55 mm | analog 4…20 mA integrated, illuminated LCD display | more | ||
![]() |
MPU-P-9701 | Programming adapter | for parametrisation MPU-4 9701 including software | more | ||
![]() |
VMU-FK, VMU-NC | Transmitter for top hat rail mounting | analog 4…20 mA input thermocouple | more | ||
![]() |
VMU-PT, ZMU-PT | Transmitter for top hat rail mounting | free parametrisation analog 4…20 mA input Pt100 | more | ||
![]() |
VTR-FK, VTR-NC | Controller for top hat rail mounting | input thermocouple, output relay | more | ||
![]() |
VTR-PT | Controller for top hat rail mounting | input Pt100, output relay | more |