Dairy, Food & Beverage

Figure Product Application Features PI CAD Details
NCS-01, NCS-02 Limit detection in metallic tanks and pipes with CLEANadapt M12 Independent of the conductivity of the medium, Extended measuring range Dk>=5
de
en
fr
ru
Interactive 3D view + Download 3D CAD model more
NCS-11, NCS-12 Limit detection in metallic tanks and pipes with CLEANadapt G1/2" Independent of the conductivity of the medium, Extended measuring range Dk>=2 for critical media (e.g. oil, fat, ...)
de
en
fr
ru
Interactive 3D view + Download 3D CAD model more
NCS-L-11, NCS-L-12 Limit detection in metallic tanks with CLEANadapt G1/2"; Version with extended sensor tip for installation from top or for pasty Media with extereme product adherence. Independent of the conductivity of the medium, Extended measuring range Dk>=2 (NCS-L-12/50) for critical media (e.g. oil, fat, ...)
de
en
fr
ru
Interactive 3D view + Download 3D CAD model more
NCS-M-11, NCS-M-12 Limit detection in metallic tanks and pipes; Process connection CLEANadapt G1/2" hygienic; compact version with small sensor head OEM-product; Independent of the conductivity of the medium, Extended measuring range Dk>=2 for critical media (e.g. oil, fat, ...)
de
en
Interactive 3D view + Download 3D CAD model more
NSS-157 Limit detection in metallic tanks and pipes with CLEANadapt G1/2" Adapted for very adhesive media
de
en
  more
NVS-041, NVS-043, NVS-046 Limit detection in metallic tanks and pipes with CLEANadapt M12 Individual shortening and twisting of the rod possible, Installation in pipes from DN15 on
de
en
cn
Interactive 3D view + Download 3D CAD model more
NVS-061, NVS-063, NVS-066, NVS-081, NVS-083, NVS-086 Limit detection in metallic tanks and pipes with CLEANadapt M12 Individual shortening and twisting of the rod possible, Installation in pipes from DN15 on
de
en
cn
Interactive 3D view + Download 3D CAD model more
NVS-110, NVS-120 Multilevel detection even in non-metallic tanks Rod- or rope-electrodes for up to 4 levels
de
en
cn
Interactive 3D view + Download 3D CAD model more
NVS-141, NVS-143, NVS-146 Limit detection in metallic tanks and pipes with CLEANadapt G1/2" Individual shortening and twisting of the rod possible, Wiring head 55mm
de
en
fr
cn
Interactive 3D view + Download 3D CAD model more
NVS-161, NVS-163, NVS-166, NVS-181, NVS-183, NVS-186 Limit detection in metallic tanks and pipes with CLEANadapt G1/2" Individual shortening and twisting of the rod possible, Wiring head 55mm
de
en
fr
cn
Interactive 3D view + Download 3D CAD model more
NVS-345 Multilevel detection with CLEANadapt G1" Individual shortening and twisting of the rod possible, for up to 4 levels
de
en
cn
Interactive 3D view + Download 3D CAD model more
NVS-50 Multilevel detection with dairy flange Dairy flange acc. To DIN 11851, Individual shortening and twisting of the rod possible
de
en
cn
Interactive 3D view + Download 3D CAD model more

 

Pharma

Figure Product Application Features PI CAD Details
NCS-01P, NCS-02P Limit detection in metallic tanks and pipes with CLEANadapt M12 Independent of conductivity of medium; Extended measuring range Dk>=5
de
en
fr
cn
  more
NCS-31P, NCS-32P Limit detection in metallic tanks and pipes with Direct Connection Direct Connections for Fermenter, Tri-Clamp, BioControl, Varivent®; Extended measuring range Dk>=5
de
en
fr
cn
Interactive 3D view + Download 3D CAD model more
NCS-61P, NCS-62P Limit detection in metallic tanks and pipes with PHARMadapt EPA-8 Connection EPA-8, for pipes down to DN10, Extended measuring range Dk>=5
de
en
fr
cn
Interactive 3D view + Download 3D CAD model more
NCS-81P, NCS-82P Limit detection in metallic tanks and pipes with PHARMadapt EPA-18 Connection EPA-18, for pipes down to DN25, Extended measuring range Dk>=2
de
en
fr
cn
Interactive 3D view + Download 3D CAD model more

 

Instrumentation & Controls

Figure Product Application Features PI CAD Details
VNV-D 1 level control and 1 level detection, 0,1-100 kOhm, 0,1-10 kOhm Active output 24 VDC, Power supply 24 VDC
de
en
  more
VNV-DU 1 level control and 1 level detection, 0,1-100 kOhm, 0,1-10 kOhm Active output 24 VDC, Power supply 24 VDC
de
en
  more
VNV-E 1 level control with switch-on / off delay; 0,1-100 kOhm Active output 24 VDC, Power supply 24 VDC
de
en
  more
VNV-S 1 level control, 0,1-100 kOhm Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
VNV-SD 1 level control, 0,1-50 kOhm Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
VNV-V 4 level detection, 0,1-100 kOhm Active output 24 VDC, Power supply 24 VDC
de
en
  more
VNV-W 1 level detection, 50 kOhm fixed Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
VNV-WD 1 level control and 1 level detection, 0,1-100 kOhm Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
VNV-WDV 1 level control and 1 level detection with switchon / off delay, 0,1-100 kOhm Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
VNV-WEV 1 level control with switch-on / off delay, 0,1-100 kOhm Relay output, Power supply 230 VAC, 115 VAC or 24 VAC
de
en
  more
ZNV-Z 2 level detection, 0,1-100 kOhm Active output 24 VDC, Power supply 24 VDC
de
en
  more


Negele Messtechnik GmbH • Raiffeisenweg 7 • D-87743 Egg an der Günz
Tel. +49 (0) 83 33 / 92 04-0 • Fax: +49 (0) 83 33 / 92 04-49 • E-Mail: vertrieb@negele.net • www.negele.net