Dairy, Food & Beverage
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
NCS-01, NCS-02 | Limit detection in metallic tanks and pipes with CLEANadapt M12 | Independent of the conductivity of the medium, Extended measuring range Dk>=5 | ![]() |
more | |
![]() |
NCS-11, NCS-12 | Limit detection in metallic tanks and pipes with CLEANadapt G1/2" | Independent of the conductivity of the medium, Extended measuring range Dk>=2 for critical media (e.g. oil, fat, ...) | ![]() |
more | |
![]() |
NCS-L-11, NCS-L-12 | Limit detection in metallic tanks with CLEANadapt G1/2"; Version with extended sensor tip for installation from top or for pasty Media with extereme product adherence. | Independent of the conductivity of the medium, Extended measuring range Dk>=2 (NCS-L-12/50) for critical media (e.g. oil, fat, ...) | ![]() |
more | |
![]() |
NCS-M-11, NCS-M-12 | Limit detection in metallic tanks and pipes; Process connection CLEANadapt G1/2" hygienic; compact version with small sensor head | OEM-product; Independent of the conductivity of the medium, Extended measuring range Dk>=2 for critical media (e.g. oil, fat, ...) | ![]() |
more | |
![]() |
NSS-157 | Limit detection in metallic tanks and pipes with CLEANadapt G1/2" | Adapted for very adhesive media | more | ||
![]() |
NVS-041, NVS-043, NVS-046 | Limit detection in metallic tanks and pipes with CLEANadapt M12 | Individual shortening and twisting of the rod possible, Installation in pipes from DN15 on | ![]() |
more | |
![]() |
NVS-061, NVS-063, NVS-066, NVS-081, NVS-083, NVS-086 | Limit detection in metallic tanks and pipes with CLEANadapt M12 | Individual shortening and twisting of the rod possible, Installation in pipes from DN15 on | ![]() |
more | |
![]() |
NVS-110, NVS-120 | Multilevel detection even in non-metallic tanks | Rod- or rope-electrodes for up to 4 levels | ![]() |
more | |
![]() |
NVS-141, NVS-143, NVS-146 | Limit detection in metallic tanks and pipes with CLEANadapt G1/2" | Individual shortening and twisting of the rod possible, Wiring head 55mm | ![]() |
more | |
![]() |
NVS-161, NVS-163, NVS-166, NVS-181, NVS-183, NVS-186 | Limit detection in metallic tanks and pipes with CLEANadapt G1/2" | Individual shortening and twisting of the rod possible, Wiring head 55mm | ![]() |
more | |
![]() |
NVS-345 | Multilevel detection with CLEANadapt G1" | Individual shortening and twisting of the rod possible, for up to 4 levels | ![]() |
more | |
![]() |
NVS-50 | Multilevel detection with dairy flange | Dairy flange acc. To DIN 11851, Individual shortening and twisting of the rod possible | ![]() |
more |
Pharma
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
NCS-01P, NCS-02P | Limit detection in metallic tanks and pipes with CLEANadapt M12 | Independent of conductivity of medium; Extended measuring range Dk>=5 | more | ||
![]() |
NCS-31P, NCS-32P | Limit detection in metallic tanks and pipes with Direct Connection | Direct Connections for Fermenter, Tri-Clamp, BioControl, Varivent®; Extended measuring range Dk>=5 | ![]() |
more | |
![]() |
NCS-61P, NCS-62P | Limit detection in metallic tanks and pipes with PHARMadapt EPA-8 | Connection EPA-8, for pipes down to DN10, Extended measuring range Dk>=5 | ![]() |
more | |
![]() |
NCS-81P, NCS-82P | Limit detection in metallic tanks and pipes with PHARMadapt EPA-18 | Connection EPA-18, for pipes down to DN25, Extended measuring range Dk>=2 | ![]() |
more |
Instrumentation & Controls
| Figure | Product | Application | Features | PI | CAD | Details |
![]() |
VNV-D | 1 level control and 1 level detection, 0,1-100 kOhm, 0,1-10 kOhm | Active output 24 VDC, Power supply 24 VDC | more | ||
![]() |
VNV-DU | 1 level control and 1 level detection, 0,1-100 kOhm, 0,1-10 kOhm | Active output 24 VDC, Power supply 24 VDC | more | ||
![]() |
VNV-E | 1 level control with switch-on / off delay; 0,1-100 kOhm | Active output 24 VDC, Power supply 24 VDC | more | ||
![]() |
VNV-S | 1 level control, 0,1-100 kOhm | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
VNV-SD | 1 level control, 0,1-50 kOhm | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
VNV-V | 4 level detection, 0,1-100 kOhm | Active output 24 VDC, Power supply 24 VDC | more | ||
![]() |
VNV-W | 1 level detection, 50 kOhm fixed | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
VNV-WD | 1 level control and 1 level detection, 0,1-100 kOhm | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
VNV-WDV | 1 level control and 1 level detection with switchon / off delay, 0,1-100 kOhm | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
VNV-WEV | 1 level control with switch-on / off delay, 0,1-100 kOhm | Relay output, Power supply 230 VAC, 115 VAC or 24 VAC | more | ||
![]() |
ZNV-Z | 2 level detection, 0,1-100 kOhm | Active output 24 VDC, Power supply 24 VDC | more |